EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 105 of 121
February 11, 2010
Figure D-8: CI 220 Pulse F2 Pulse Characteristics
Pulse F2 - Parameters
U
p
13.5 V
U
s
10 V
t
r
1 ± 0.5 ms
t
f
1 ± 0.5 ms
t
6
1 ± 0.5 ms
t
d
0.2 – 2 s
R
i
< 0.5 ohms
Parameters listed are for open circuit
conditions.
U
P
U
S
0.1U
P
0.9U
P
t
f
V
D.3 Test Pulses G1 and G2
Pulse G1 represents the transient produced due to sudden disconnection of the battery from the alternator. The test pulse is
equivalent to Test Pulse 5a delineated in ISO 7637-2 (2004-06-15). Pulse G1 characteristics are illustrated in Figure D-9.
Pulse G2 represents a voltage clamped transient produced due to sudden disconnection of the battery from an alternator fitted
with Central Load Dump (CLD) Protection. Pulse G2 characteristics are illustrated in Figure D-10.
Figure D-9: CI 220 Pulse G1 Characteristics
Pulse G1 - Parameters
Open Circuit Conditions
U
p
13.5 V
U
s
60.V
t
r
10 ( -5 /+0 ) ms
t
d
300 ms +/-20%
R
i
0.5 Ohms
Loaded Conditions ( R
L
= R
i
)
U
p
13.5 V
U
s
30 V
t
r
10 ( -5 /+0 ) ms
t
d
150 mS +/-20%
R
i
0.5 Ohms
Waveform voltage begins and ends at Up
All voltage values are with respect to 0 volts
unless otherwise specified.
U
P
V